Question
A single-phase full bridge inverter fed by a 325 V DC produces a symmetric quasi-square waveform across “ab” as shown. To achieve a modulation index of 0.8, the angle θ expressed in degrees should be _______. (Round off to 2 decimal places)
Answer :
51.07